FaultScore

1996 Ford F-150 fuel system problems

57 of the 383 complaints about the 1996 Ford F-150 are about the fuel system — 15% of everything reported for this model year. Half of the failures with a mileage on record happened before 104,375 miles.

C

57

Complaints

1

Crashes

1

Fires

3

Injuries

Exactly what failed

Selector Devices 13 22.8%
Fuel System, Gasoline 12 21.1%
Auxillary Tank 7 12.3%
Fuel/Propulsion System 6 10.5%
Delivery 4 7.0%
Fuel Pump 3 5.3%
Tank Assembly 2 3.5%
Hoses, Lines/Piping, AND Fittings 2 3.5%
Fuel Pump 2 3.5%
Fuel System, Other 1 1.8%

Fuel & Propulsion across every Ford F-150 year

1990 12 0.4%
1991 165 4.9%
1992 258 7.6%
1993 309 9.1%
1994 121 3.6%
1995 68 2.0%
1996 57 1.7%
1997 269 7.9%
1998 212 6.3%
1999 144 4.3%
2000 166 4.9%
2001 147 4.3%
2002 89 2.6%
2003 46 1.4%
2004 77 2.3%
2005 82 2.4%
2006 60 1.8%
2007 55 1.6%
2008 27 0.8%
2009 22 0.6%
2010 58 1.7%
2011 118 3.5%
2012 120 3.5%
2013 160 4.7%
2014 72 2.1%
2015 78 2.3%
2016 95 2.8%
2017 25 0.7%
2018 62 1.8%
2019 24 0.7%
2020 14 0.4%
2021 81 2.4%
2022 84 2.5%
2023 10 0.3%

What owners said

Filed with NHTSA, in their own words.

at 130,000 miles Kernersville, NC

FUEL SYSTEM, GASOLINE:DELIVERY:FUEL PUMP

The contact owns a 1996 Ford F-150. The contact stated while driving 45 MPH, the vehicle started to shutoff and restart independently. The check engine warning light was illuminated. The vehicle was diagnosed by an independent mechanic. The mechanic informed the contact that the rear tank’s fuel pump needed to be replaced. The vehicle was not repaired. The manufacturer was made aware of the failure and confirmed that there was no open recall associated with the VIN for the failure. The failure mileage was approximately 130,000. The contact stated there is an issue with the front fuel tank feeding fuel into the rear tank when the rear tank pump is not operational and having to switch the fuel supply over to the front tank. When the rear tank is full from the front tank feed, it spills over out of the rear tank fill spout, and runs out on the ground.

NHTSA complaint #11540729 — an unverified report by a vehicle owner.

Spring, TX

FUEL/PROPULSION SYSTEM

The front fuel tank is overflowing when I run the vehicle with the rear tank. The return fuel is always to the front tank causing it to overflow its a hazardous situation.

NHTSA complaint #11473139 — an unverified report by a vehicle owner.

at 111,500 miles Richardson, TX

FUEL/PROPULSION SYSTEM

FUEL FROM REAR TANK FILLS FRONT TANK.IT CAN OVERFLOW CAUSING A FIRE.

NHTSA complaint #11362648 — an unverified report by a vehicle owner.

at 88,000 miles Wilmington, NC

FUEL/PROPULSION SYSTEM

FUEL FLOWS OUT THE FRONT TANK WHEN USING THE REAR TANK AND THE FRONT ON IS FULL !! FOUND THIS WHEN PARKED IN MY GARAGE .

NHTSA complaint #10938604 — an unverified report by a vehicle owner.

Carrollton, GA

FUEL/PROPULSION SYSTEM

FUEL FROM THE FRONT TANK IS OVERFLOWING FUEL INTO THE REAR FUEL TANK AND VICE VERSA. THIS HAS BEEN HAPPENING FOR YEARS BUT NO ONE SEEMS TO KNOW HOW TO REPAIR OR WHAT IS CAUSING THE ISSUE.

NHTSA complaint #10811833 — an unverified report by a vehicle owner.

at 120,000 miles SAN Antonio, TX

FUEL/PROPULSION SYSTEM

FUEL KEEPS LEAKING FROM SECOND TANK SOMEWHERE TOWARDS THE OPENING.BEEN LIKE THIS SINCE THE DATE I HAVE REPORTED TILL NOW BUT NEVER THOUGHT MUCH ABOUT IT UNTIL REVIEWING CASE NHTSA ID NUMBER: [XXX] AND NHTSA REF # 10587059 INFORMATION REDACTED PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6).

NHTSA complaint #10683764 — an unverified report by a vehicle owner.

at 120,000 miles Akron, PA

FUEL SYSTEM, GASOLINE

TL* THE CONTACT OWNS A 1996 FORD F-150. THE CONTACT STATED THAT THE VEHICLE WAS EQUIPPED WITH A DUAL FUEL TANK AND WHILE DRIVING VARIOUS SPEEDS, A STRONG ODOR OF GASOLINE EMITTED INSIDE AND OUTSIDE OF THE VEHICLE. THE VEHICLE WAS TAKEN TO AN AUTHORIZED DEALER, WHO STATED THAT THE FUEL RETURN CHECK VALVE WOULD NEED TO BE REPLACED BECAUSE THE FUEL FROM THE REAR FUEL TANK OVERFLOWED INTO THE SECOND FUEL TANK. IN ADDITION, FUEL HAD SEEPED OUT OF THE FUEL TANK CAP. THE VEHICLE WAS NOT REPAIRED. THERE WAS A RECALL ISSUED FOR 1990-1993 F-SERIES MODEL VEHICLES UNDER NHTSA CAMPAIGN ID NUMBER: 01I008000 (FUEL SYSTEM, GASOLINE) BUT NOT FOR THE 1996 MODEL YEARS. THE MANUFACTURER WAS NOTIFIED OF THE DEFECT. THE APPROXIMATE FAILURE MILEAGE WAS 120,000. UPDATED 06/30/14 MA UPDATED 07/2/2014

NHTSA complaint #10587059 — an unverified report by a vehicle owner.

at 105,000 miles Austin, TX

FUEL/PROPULSION SYSTEM

TL* THE CONTACT OWNS A 1996 FORD F-150. THE CONTACT NOTICED FUEL LEAKING FROM THE FILLER CAP. AFTER INSPECTING THE VEHICLE, THE CONTACT NOTICED THAT THE FUEL FROM THE REAR FUEL TANK WAS SPILLING INTO THE FRONT FUEL TANK, CAUSING IT TO OVERFLOW AND LEAK. THE VEHICLE WAS NOT TAKEN TO THE DEALER FOR DIAGNOSTIC. THE VEHICLE WAS NOT REPAIRED. THE APPROXIMATE FAILURE MILEAGE WAS 105,000.

NHTSA complaint #10463596 — an unverified report by a vehicle owner.

at 122,700 miles Mountain TOP, PA

FUEL SYSTEM, GASOLINE

TL* THE CONTACT OWNS A 1996 FORD F-150. THE CONTACT STATED WHILE DRIVING APPROXIMATELY 20 MPH THE FUEL TANK DETACHED FROM THE VEHICLE. APPROXIMATELY 3 GALLONS OF FUEL SPILLED OUT OF THE VEHICLE. THE VEHICLE WAS TOWED TO AN INDEPENDENT MECHANIC WHO ADVISED HIM THAT BOTH STRAPS WERE SEVERELY COVERED WITH RUST AND NEEDED TO BE REPLACED ALONG WITH THE FUEL TANK. BOTH STRAPS AND THE FUEL TANK WERE REPAIRED. THE MANUFACTURER WAS CONTACTED REGARDING THE FAILURE AND STATED HIS VIN WAS NOT INCLUDED IN ANY RECALLS. THE FAILURE MILEAGE WAS APPROXIMATELY 122,700.

NHTSA complaint #10430047 — an unverified report by a vehicle owner.

at 145,000 miles Monroe, MO

FUEL SYSTEM, GASOLINE

PRIMARY FUEL TANK STRAPS BROKEN, TANK RESTING ON SKID PLATE. SECONDARY FUEL TANK STRAPS CORRODING.

NHTSA complaint #10428117 — an unverified report by a vehicle owner.

at 100,000 miles Birmingham, AL

FUEL SYSTEM, GASOLINE

TL* THE CONTACT OWNS A 1998 FORD F-150. WHILE THE VEHICLE WAS PARKED THE CONTACT NOTICED FUEL LEAKING FROM THE FUEL TANK. THERE WAS A NHTSA RECALL CAMPAIGN ID NUMBER: 98V161000 (FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY) THAT MAY BE RELATED TO THE FAILURE. THE DEALER WAS MADE AWARE OF THE FAILURE AND STATED THE VIN WAS NOT INCLUDED IN THE RECALL. THE VEHICLE WAS NOT REPAIRED. THE APPROXIMATE FAILURE MILEAGE WAS 100,000.

NHTSA complaint #10425158 — an unverified report by a vehicle owner.

at 92,000 miles Oxford, CT

FUEL SYSTEM, GASOLINE

TL* THE CONTACT OWNS A 1996 FORD F150. THE CONTACT STATED THAT THE FRONT FUEL TANK STRAP WAS CORRODED AND CAUSED A LEAK IN THE FUEL TANK. HE TOOK THE VEHICLE TO A LOCAL MECHANIC WHO REPAIRED THE STRAP BUT DID NOT REMEDY THE ISSUE WITH THE FUEL LEAK. THE CONTACT THEN SWITCHED TO USING THE REAR FUEL TANK, IN WHICH HE SOON DISCOVERED THAT THE THERE WAS ALSO A LEAK COMING FROM THE REAR TANK. THE MANUFACTURER WAS CONTACT WHO STATED THAT THERE WERE NO RECALLS FOR THE FAILURE AND OFFERED NO FURTHER ASSISTANCE. THE CONTACT PROCEEDED TO FILE A CLAIM WITH THE MANUFACTURER. THE FAILURE MILEAGE WAS 92,000.

NHTSA complaint #10420038 — an unverified report by a vehicle owner.

at 80,000 miles Lecanto, FL

FUEL SYSTEM, GASOLINE

TL*THE CONTACT OWNS A 1996 FORD F150. THE CONTACT STATED THAT FUEL WAS FLOWING FROM THE REAR FUEL PUMP AND INTO THE FRONT FUEL PUMP, CAUSING AN OVERFLOW AND ABNORMAL LEAKAGE. THE MANUFACTURER WAS CONTACTED AND THEY ADVISED THE CONTACT THAT SOMEONE WOULD RETURN HIS CALL BUT TO NO AVAIL. THE VEHICLE WAS TAKEN TO THE DEALER WHO PERFORMED A DIAGNOSTIC THAT LOCATED THE FAILURE AT THE FRONT FUEL PUMP CHECK VALVE. THE VEHICLE WAS NOT REPAIRED. THE FAILURE MILEAGE WAS 80,000 AND THE CURRENT MILEAGE WAS 83,553.

NHTSA complaint #10396991 — an unverified report by a vehicle owner.

at 160,000 miles Overland, MO

FUEL SYSTEM, GASOLINE

TL*THE CONTACT OWNS 1996 FORD F150. THE CONTACT ATTEMPTED TO START THE VEHICLE AND IT WOULD NOT START; HOWEVER, AFTER SWITCHING TO THE REAR FUEL TANK THE VEHICLE STARTED. THE FRONT FUEL TANK HAD APPROXIMATELY A HALF TANK OF FUEL IN IT AT THE TIME. THE CONTACT NOTICED THAT THE FUEL WAS LEAKING IN THE FRONT FUEL TANK. THE FUEL WAS OVERFLOWING FROM THE BACK TO THE FRONT FUEL TANK CAUSING A LEAK AND A FUEL ODOR. THE VEHICLE WAS NOT TAKEN TO THE DEALER FOR DIAGNOSTIC TESTING OR TO BE REPAIRED. THE APPROXIMATE FAILURE MILEAGE WAS 160,000.

NHTSA complaint #10386958 — an unverified report by a vehicle owner.

at 109,000 miles Charlotte, NC

FUEL SYSTEM, GASOLINE

I OWN A 1996 FORD F150 WITH DUAL TANKS. I HAVE A PROBLEM WITH THE BACK FUEL TANK TRANSFERRING GAS TO THE FRONT TANK. IF UNNOTICED THIS WILL CAUSE GAS TO OVERFLOW ONTO THE GROUND CAUSING A REAL SAFETY AND POLLUTION HAZARD. I CALLED FORD AND THEY SAID THAT THERE WASN'T ANY RECALL FOR THIS PROBLEM ON MY VIN. WELL EVEN IF THERE ISN'T A RECALL FOR THIS PROBLEM OR NOT IT IS STILL A PROBLEM AND THERE WAS A RECALL FOR THIS PROBLEM ON THE 1990 TP 1993 F150 SO I'M FIGURING THAT THEY STILL HAVE THE PROBLEM ON MY VEHICLE ALSO.

NHTSA complaint #10352940 — an unverified report by a vehicle owner.

at 104,000 miles Milton, FL

FUEL SYSTEM, GASOLINE

TL*THE CONTACT OWNS A 1996 FORD F-150. WHENEVER THE CONTACT WOULD ATTEMPT TO STOP THE VEHICLE, IT WOULD TURN OFF AND FAIL TO RESTART. THE VEHICLE WAS TAKEN TO THE DEALER AND THEY STATED THAT THE FUEL PRESSURE REGULATOR NEEDED TO BE REPLACED. THE CONTACT ALSO NOTICED THAT THE SECOND FUEL TANK WAS TRANSFERRING FUEL TO THE FIRST FUEL TANK. THERE WERE NO WARNINGS PRIOR TO THE FAILURES. THE CURRENT AND FAILURE MILEAGES WERE 104,000.

NHTSA complaint #10275607 — an unverified report by a vehicle owner.

at 102,000 miles Lonsdale, AR

FUEL SYSTEM, GASOLINE

TL*THE CONTACT OWNS A 1996 FORD F-150. THE CONTACT STATED THAT FUEL BEGAN TO LEAK FROM THE VEHICLE WHILE IT WAS PARKED. HE OPENED THE FUEL CAP AND GAS POURED OUT. THE DEALER STATED THAT A REGULATOR OR A FUEL PUMP NEEDED TO BE REPLACED. THE MANUFACTURER STATED THAT THERE IS A RECALL, BUT THE VEHICLE IS NOT INCLUDED. THE CURRENT AND FAILURE MILEAGES WERE 102,000.

NHTSA complaint #10196565 — an unverified report by a vehicle owner.

at 90,000 miles Midlothian, VA

FUEL SYSTEM, GASOLINE:DELIVERY

THE VEHICLE HAS 2 FUEL TANKS. WHILE DRIVING, GASOLINE FLOWS FROM ONE TANK TO THE SECOND TANK, CAUSING THE SECOND TANK TO OVERFILL. WHEN OPENING THE LID TO THE SECOND TANK, PRESSURE CAUSED BY EXCESSIVE AMOUNT OF GASOLINE CAUSES GASOLINE TO SPEW FROM THE SPOUT ONTO OPERATOR AND ONTO THE GROUND.

NHTSA complaint #10183538 — an unverified report by a vehicle owner.

at 90,000 miles Midlothian, VA

FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY

THE VEHICLE HAS 2 FUEL TANKS. WHILE DRIVING, GASOLINE FLOWS FROM ONE TANK TO THE SECOND TANK, CAUSING THE SECOND TANK TO OVERFILL. WHEN OPENING THE LID TO THE SECOND TANK, PRESSURE CAUSED BY EXCESSIVE AMOUNT OF GASOLINE CAUSES GASOLINE TO SPEW FROM THE SPOUT ONTO OPERATOR AND ONTO THE GROUND.

NHTSA complaint #10183538 — an unverified report by a vehicle owner.

at 105,000 miles Erie, PA

FUEL SYSTEM, OTHER:DELIVERY:HOSES, LINES/PIPING, AND FITTINGS

DT*: THE CONTACT STATED WHILE THE VEHICLE WAS STOPPED TO REFUEL, THE GAS CAP WAS REMOVED AND GASOLINE BLEW OUT OF THE FILLER PIPE. THERE WAS A RECALL #93V125000 FOR A SIMILAR PROBLEM WITH 1990-1993 FORD F-150 MODELS THAT CAUSED FUEL OVERFLOW DUE TO A MALFUNCTION OF THE CHECK VALVE BETWEEN THE DUEL TANKS. THE CONTACT HAS CONTACTED THE SERVICE DEALER AND THE MANUFACTURER.

NHTSA complaint #10164309 — an unverified report by a vehicle owner.

at 30,000 miles Amherst, WI

FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY

DT*: THE CONTACT STATED THE CHECK VALVE IN THE FUEL PUMP ASSEMBLY MALFUNCTIONED AND THE UNUSED FUEL TRANSFERRED FROM ONE TANK TO ANOTHER. NO SPILLAGE OCCURRED BECAUSE THE SECOND TANK WAS NOT OVERFILLED. THERE IS A NHTSA RECALL, # 93V125000, REGARDING THE FUEL SYSTEM ASSEMBLY. THE VEHICLE HAS THE SAME PROBLEMS AS INDICATED IN THE RECALL; HOWEVER IT IS NOT INCLUDED IN THE RECALL DUE TO THE VIN. THE VEHICLE HAS NOT BEEN INSPECTED.

NHTSA complaint #10149039 — an unverified report by a vehicle owner.

at 207,000 miles Saucier, MS

FUEL SYSTEM, GASOLINE

FUEL TANKS. FILLED REAR TANK AND OPENED FRONT TANK TO FILL IT. WHEN I TOOK CAP OFF GAS SPLASHED OUT. THE FRONT TANK WAS OVER FULL. I TALKED TO A FORD MECHANIC AND HE TOLD ME THAT IT WAS A VALVE IN THE RETURN LINE THAT CAUSED THE FRONT TANK TO OVER FILL FROM THE REAR TANK. HE ALSO SAID THAT FORD DID REPAIR SOME TRUCKS ,BUT WASN'T DOING IT NOW.

NHTSA complaint #10145180 — an unverified report by a vehicle owner.

at 72,000 miles Lacrescent, MN

FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES

DT: THE CONTACT OWNS A 1996 FORD F150. THE CONTACT STATED THE VEHICLE HAS A DUEL GASOLINE TANK. WHEN THE BACK TANK IS SELECTED IT WILL PUMP GASOLINE TO THE ENGINE, BUT IT WILL ALSO PUMP GASOLINE INTO THE FRONT TANK AND PRESSURIZE THE GASOLINE, FORCING IT OUT OF THE FILLER NECK AND CAP. WHEN THE VEHICLE IS PARKED GASOLINE OVERFLOWS ONTO THE GROUND, AND WHEN DRIVING THE VEHICLE, THE GASOLINE SPILLS OUT ALONG THE HIGHWAY. WHEN THE CAP IS REMOVED FROM THE TANK, A LARGER AMOUNT OF GASOLINE WILL SPILL OUT, AND THE GASOLINE IS FILLED UP TO THE FILLER NECK. THE CONSUMER HAS TO WATCH THE AMOUNT OF GASOLINE THAT IS IN THE BACK TANK TO ENSURE THAT THE OVERFLOW WILL NOT OCCUR. THE SERVICE DEALER SAID THAT THE CHECK VALVE HAD TO BE REPLACED. THE CHECK VALVE PREVENTED THE GASOLINE FROM GOING FROM THE BACK TANK INTO THE FRONT TANK. THE MANUFACTURER SAID THEY WOULD NOT COVER THE COST FOR THE REPAIR.*AK UPDATED 01/04/06.

NHTSA complaint #10138652 — an unverified report by a vehicle owner.

at 104,751 miles Youngtown, AZ

FUEL SYSTEM, OTHER:DELIVERY:FUEL PUMP

NORMAL DRIVING. STOPPED TO REFUEL. UPON ATTEMPTING TO OPEN REAR GAS CAP PRESSURE BLEW CAP OFF AND LARGE AMOUNT FUEL ALL OVER ME AND THE SIDE OF THE TRUCK. *AK CONDITION NOT REPAIRED AS YET.

NHTSA complaint #10116575 — an unverified report by a vehicle owner.

at 187,799 miles Anthony, FL

FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK

DUAL GAS TANKS. GAS IS PRESSURIZED FROM REAR TANK TO THE FRONT TANK, CAUSING A FUEL TRANSFER TO THE FRONT TANK, FRONT TANK IS OVERFILLING, GAS IS UNDER PRESSURE, SPILLING FROM THE OVERFLOW. WHEN THE CAP IS REMOVED, GAS EXPLODES FROM THE FILLER NECK.

NHTSA complaint #10110560 — an unverified report by a vehicle owner.

at 187,799 miles Anthony, FL

FUEL SYSTEM, GASOLINE

DUAL GAS TANKS. GAS IS PRESSURIZED FROM REAR TANK TO THE FRONT TANK, CAUSING A FUEL TRANSFER TO THE FRONT TANK, FRONT TANK IS OVERFILLING, GAS IS UNDER PRESSURE, SPILLING FROM THE OVERFLOW. WHEN THE CAP IS REMOVED, GAS EXPLODES FROM THE FILLER NECK.

NHTSA complaint #10110560 — an unverified report by a vehicle owner.

at 82,931 miles Springfield, MO

FUEL SYSTEM, GASOLINE:DELIVERY:FUEL PUMP

THE VEHICLE HAD DUAL GAS TANKS. THE FRONT TANK WAS LEAKING FUEL OUT OF THE CAP SINCE THE FUEL FROM THE BACK TANK WAS TRAVELING TO THE FRONT. *AK THE DEALER REPLACED THE FUEL PUMP. *BF

NHTSA complaint #10101252 — an unverified report by a vehicle owner.

Tucson, AZ

FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES

FUEL LEAKS FROM THE FRONT TANK VENT CAP DOWN THE VEHICLE SIDE TO THE GROUND. OCCURS REGULARLY WHEN BOTH TANKS ARE FILLED AND REAR TANK IS USED FIRST. HAVE TO SWITCH BETWEEN TANKS FREQUENTLY TO KEEP CONTENTS FROM OVERFLOWING. THIS IS A KNOWN PROBLEM. NOT ENOUGH PEOPLE DEAD YET? RECALL IT.

NHTSA complaint #10093065 — an unverified report by a vehicle owner.

at 120,000 miles Mays Landing, NJ

FUEL SYSTEM, OTHER:DELIVERY:FUEL PUMP

1996 FORD F-150 DUAL GASOLINE TANKS, FRONT FUEL PUMP FAILURE CAUSES REAR FUEL TANK TO PRESSURIZE FRONT FUEL TANK, CAUSING FUEL TO LEAK FROM FRONT FUEL TANK FILL PIPE, FRONT TANK IS CAUSED TO BE OVERFILLED AND UNDER PRESSURE, UPON REMOVAL OF FRONT FILL CAP WITH OR WITHOUT VEHICLE IGNITION ON, GASOLINE IS RELEASED IN SPRAY AND LIQUID FORM APPROXIAMATELY 1/2 TO 1 GALLON OF GASOLINE AT A TIME CAUSING A SEVERE FIRE/EXPLOSION HAZARD.

NHTSA complaint #10074949 — an unverified report by a vehicle owner.

at 85,000 miles Chillicothe, OH 1 injured

FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK

DUAL GAS TANKS. GAS IS PRESSURIZED FROM REAR TANK TO THE FRONT TANK. CAUSING A FUEL TRANSFER TO THE FRONT TANK, FRONT TANK IS OVERFILLING, GAS IS UNDER PRESSURE, SPILLING FROM THE OVERFLOW. WHEN THE CAP IS REMOVED, GAS EXPLODES FROM THE FILLER NECK.

NHTSA complaint #10064015 — an unverified report by a vehicle owner.

Other 1996 Ford F-150 problems

← Full 1996 Ford F-150 report